Abstract:Under the condition of weak grid,the dynamic interactions between multi-inverters and between multi-inverters and the grid affect the power quality and stability of the power system,which is likely to cause harmonic resonance. In order to study the harmonic resonance characteristics of the single-stage photovoltaic grid-connected multi-inverter system,the modal analysis method is used for systematical analysis and discussion on the resonance problem while the interaction between the photovoltaic generation and the system is considered. Firstly,according to the structure and control strategy of three-phase single-stage photovoltaic grid-connected system,the Thevenin equivalent model for the multi-inverter system is established. Secondly,a modal analysis method is applied,which can determine the system resonance frequency,resonance center and the participation degree of each node by constructing node admittance matrix of the multi-inverter system. The resonance characteristics and variation laws of the system are studied from three aspects:the number of inverters,external environment and transmission distance. Finally,with the use of MATLAB/Simulink simulation platform,the correctness and effectiveness of the modal analysis method are validated by a simulation model of a three-phase single-stage photovoltaic grid-connected multi-inverter system. The results show that when the number of inverters increases,the low resonance frequency tends to decrease,which is 30th,27th,and 25th harmonics respectively,while the high resonance frequency remains unchanged at 2 230 Hz. When the ambient temperature decreases,the low resonance frequency increases gradually,which is 22th,23th,and 24th harmonics respectively,and the high resonance frequency is stable at about 2 225 Hz. When the transmission distance increases,the low and high resonance frequencies gradually decrease and become close to each other.
JALILI K, BERNET S. Design of LCL filters of active-front-end two level voltage-source converters[J]. IEEE Trans on Industrial Electronics, 2009, 56(5): 1674-1689
[2]
丁明,王伟胜,王秀丽,等. 大规模光伏发电对电力系统影响综述[J]. 中国电机工程学报,2014,34(1): 1-14DING Ming, WANG Weisheng, WANG Xiuli, et al. A review on the effect of large-scale PV generation on power systems[J]. Proceedings of the CSEE, 2014, 34(1): 1-14
[3]
刘怀远,徐殿国,武健,等. 并网换流器系统谐振的分析、检测与消除[J]. 中国电机工程学报,2016,36(4): 1061-1074LIU Huaiyuan, XU Dianguo, WU Jian, et al. Analysis,detection and mitigation of resonance in grid-connected converter systems[J]. Proceedings of the CSEE, 2016, 36(4): 1061-1074
[4]
张兴,余畅舟,刘芳,等. 光伏并网多逆变器并联建模及谐振分析[J]. 中国电机工程学报,2014,34(3): 336-345ZHANG Xing, YU Changzhou, LIU Fang, et al. Modeling and resonance analysis of multi-paralleled grid-tied inverters in PV systems[J]. Proceedings of the CSEE, 2014, 34(3): 336-345
[5]
王振浩,孙玮澳,孙福军. 光伏系统并网的多逆变器并联交互影响分析[J]. 电力电子技术,2017,51(2): 29-32WANG Zhenhao, SUN Weiao, SUN Fujun. Interaction analysis of multiple paralleled inverters in photovoltaic system[J]. Power Electronics, 2017, 51(2): 29-32
[6]
唐振东,杨洪耕,袁林. 弱电网下多逆变器并网控制通道间的交互影响分析[J]. 电网技术,2016,40(11): 3524-3531TANG Zhendong, YANG Honggeng, YUAN Lin. Analysis on interactive influences among control loops of multi inverters connected to weak-structured power system[J]. Power System Technology, 2016, 40(11): 3524-3531
[7]
胡伟,孙建军,马谦,等. 多个并网逆变器间的交互影响分析[J]. 电网技术,2014,38(9): 2511-2518HU Wei, SUN Jianjun, MA Qian, et al. Analysis on interactive influences among multi grid-connected inverters[J]. Power System Technology, 2014, 38(9): 2511-2518
[8]
HE J. Investigation and active damping of multiple resonances in a parallel-inverter-based microgrid[J]. IEEE Transactions on Power Electronics, 2013, 28(1): 234-246
[9]
严干贵,常青云,黄亚峰,等. 弱电网接入下多光伏逆变器并联运行特性分析[J]. 电网技术,2014,38(4): 933-940YAN Gangui, CHANG Qingyun, HUANG Yafeng, et al. Analysis on parallel operational characteristics of multi photovoltaic inverters connected to weak-structured power system[J]. Power System Technology, 2014, 38(4): 933-940
[10]
许德志,汪飞,毛华龙,等. 多并网逆变器与电网的谐波交互建模与分析[J]. 中国电机工程学报,2013,33(12): 64-71,187XU Dezhi, WANG Fei, MAO Hualong, et al. Modeling and analysis of harmonic interaction between multiple grid-connected inverters and the utility grid[J]. Proceedings of the CSEE, 2013, 33(12): 64-71,187
[11]
孙振奥,杨子龙,王一波,等. 光伏并网逆变器集群的谐振原因及其抑制方法[J]. 中国电机工程学报,2015,35(2): 418-425SUN Zhenao, YANG Zilong, WANG Yibo, et al. The cause analysis and suppression method of resonances in clustered grid-connected photovoltaic inverters[J]. Proceedings of the CSEE, 2015, 35(2): 418-425
[12]
XU W, HUANG Z Y, CUI Y, et al. Harmonic resonance mode analysis[J]. IEEE Transactions on Power Delivery, 2005, 20(2): 1182-1190
[13]
仰彩霞,刘开培,李建奇,等. 谐波谐振模态灵敏度分析[J]. 电工技术学报,2011,26(增刊1): 207-212.YANG Caixia,LIU Kaipei,LI Jianqi,et al. Modal sensitivity analysis for harmonic resonance[J]. Transac-tions of China Electrotechnical Society,2011,26(S1): 207-212.
[14]
孙东,姚玉洁,刘玉林,等. 配电网谐波谐振改进模态分析方法的研究[J]. 电力电容器与无功补偿,2017,38(2): 105-110SUN Dong, YAO Yujie, LIU Yulin, et al. Study on improved mode analysis method of harmonic resonance in distribution grid[J]. Power Capacitor & Reactive Power Compensation, 2017, 38(2): 105-110
[15]
艾欣,雷之力,崔明勇. 微电网谐波谐振的模态检测法研究[J]. 中国电机工程学报,2009,29(增刊1): 55-60AI Xin, LEI Zhili, CUI Mingyong. Study on modal survey method of the harmonic resonance in micro-grid[J]. Proceedings of the CSEE, 2009, 29(S1): 55-60
[16]
谈萌,彭祥华,王同勋,等. 基于模态分析的半波长交流输电系统与风电场并网谐振研究[J]. 高电压技术,2018,44(1): 90-98TAN Meng, PENG Xianghua, WANG Tongxun, et al. Study on the harmonic resonance of grid-connected of wind farms and half-wavelength AC transmission system based on modal analysis method[J]. High Voltage Engineering,Electric Power Automation Equipment, 2018, 44(1): 90-98
[17]
唐振东,杨洪耕. 基于模态分析的风电场并网谐波谐振研究[J]. 电力自动化设备,2017,37(3): 87-92,99TANG Zhendong, YANG Honggeng. Research on wind farm harmonic resonance based on modal analysis[J]. Electric Power Automation Equipment, 2017, 37(3): 87-92,99